Steam Autoclave is designed and manufactured for the purpose of sterilizing:
-   Medical instruments, surgical instruments, medical supplies, medical materials, etc…
-   Protective clothes, caps, gloves, mask, etc for medical doctors, medical staffs and patient,etc…
-   Instrument, materials for test, experiment in laboratory…
-   Liquid in medicine, test, experimental laboratory… in both wrapped and unwrapped types.

Main features

-   Operating by a high precision multifunctional microprocessor controller, user interface via LCD display and keypad.
-   Automatic operations from start to end of sterilizing cycle: water supply – pre vacuum – heating – sterilizing – ventilation – post vacuum drying – air balance – finish (end cycle).
-   Sterilant: Saturated steam at high temperature.
-   Equipped with PT 100 sensor to monitor temperature of the sterilization chamber.
-   Display on LCD display for: Name of phases of the sterilization cycle. Chart of phases of the sterilization cycle. Pre-set temperature and actually operating temprature. Pre-set time (sterilization, dry) and remaining time.
-   Actual sterilization pressure in the process of operation is indicated in pressure gauge.
-   Alarms by signal lights and display alarm message on LCD display.
-  Equipped with door locking system and protection function for temperature, pressure, sensor, control signal, water level, electric current, etc…

Technical data

Model
HA-80L
HA-80DR
HA-100L
HA-100DR
Type
Floor Standing. Hinged Circular Door, Swing out, Horizontal Opening.
Single Door and Double Door available to choose.
Chamber
Horizontal Cylinder
Volume
80 litre
100 litre
Temp. & Time Controller
            Fully Automatic Microprocessor Controller.
Programs
5 Pre-set Sterilization Programs (for wrapped articles, un-wrapped articles, liquid),
1 Program reserves for the user himself set-up and 1 Warm up Program. 1 Leakage Test Program and 1 Bowie – Dick Test Program. Expansion of up to 15 programs is available.
Terilization Temp. Setting Range
105°C ÷ 135°C
Sterilization Pressure Range
0.5 ÷ 2.3 kg/cm² (equivalent to 0.49 bar – 2.256 bar).
Sterilization Time Setting Range
1 ÷ 180 minutes. Setting scale: 1 minute.
Drying Time Setting Range
0 ÷ 180 minutes. Setting scale: 1 minute.
Drying Method
Electric (Model: HA-xxxL)
Vacuum Pump (Model: HA-xxxDR)

Catalogue/Brochure

** Please do not hesitate to contact us for more informations