Internal Internal

Do you already have an account? Log in

X Đóng lại
Search

Applications

Steam Autoclave is designed and manufactured for the purpose of sterilizing:
- Medical instruments, surgical instruments, medical supplies, medical materials, etc…
- Protective clothes, caps, gloves, mask, etc for medical doctors, medical staffs and patient,etc…
- Instrument, materials for test, experiment in laboratory…
- Liquid in medicine, test, experimental laboratory… in both wrapped and unwrapped types.

Main features

- Fully Automatic Programmable Logic Controller via color touch screen from start to end of sterilizing cycle: pre vacuum – heating – sterilizing – ventilation – post vacuum drying – air balance – gasket opening – door opening – finish (end cycle).
- Sterilant: Saturated steam at high temperature.
- Method of air removal: Vacuum
- Automatic water supply.
- Equipped with PT 100 sensor to monitor temperature of the sterilization chamber.
- Display on Color Touch Screen for: Name of phases of the sterilization cycle. Diagram of phases of the sterilization cycle. Pre-set temperature and actually operating temprature. Pre-set time (sterilization, dry) and remaining time. Actual sterilization pressure are in the process of operation.
- Visual and audible alarms: By signal lights, buzzer and display alarm messages on color touch screen. Equipped with automatic safety door locking system and protection function for temperature, pressure, sensor, control signal, water level, electric current, etc…

Technical data

Model
HA-820DR
HA-900DR
HA-1000DR
HA-1500DR
HA-2000DR
Type
Floor Standing. Fully Automatic Vertical Sliding Door.
Single Door and Double Door available to choose.
Chamber
Horizontal Rectangular.
Volume
820 litre
900 litre
1000 litre
1500 litre
2000 litre
Temp. & Time Controller
Fully Automatic Programmable PLC Controller.
Programs
- 12 Pre-set Sterilization Programs (for wrapped articles, un wrapped articles, liquid)
- 1 Program reserves for the user himself set-up and 1 Warm up Program
- 1 Leakage Test Program
- 1 Bowie – Dick Test Program
Sterilization Temp. Setting Range
105°C ÷ 135°C. Setting by entering digits directly with arbitrary adjustment scale.
Sterilization Pressure Range
0.5 ÷ 2.3 kg/cm² (equivalent to 0.49 bar – 2.256 bar).
Sterilization Time Setting Range
1 ÷ 180 minutes. Setting by entering digits directly with arbitrary adjustment scale.
Drying Time Setting Range
0 ÷ 180 minutes. Setting by entering digits directly with arbitrary adjustment scale.
Drying Method
Vacuum Pump.
Steam Generator
Buit-in Steam Generator.

Catalogue/Brochure

** Please do not hesitate to contact us for more informations